Production hall and installed transducers at Depoint Factory

Depoint Factory

Audio system design & integration

Sound, announcements and control. Connected across an operating factory.

18 functional areas28 audio zones24 paging zones

Commercial & Industrial Complexes

Six months of engineering in a working factory

The scale of Depoint Factory and the variety of its spaces presented a demanding engineering brief from the outset. Gol Asaye Sarma needed one system for paging, crisis announcements and quality background music across three working shifts. Approximately six months of continuous work brought together Ecler equipment, Dante audio transport, central control and custom Persian operating panels.

The challenge

Installation took place in an operating factory with 18 distinct areas, from offices, a showroom and dining spaces to stock warehouses and the main production hall. The main hall’s ceiling reached 22 metres, and measurements at planned transducer positions recorded machinery noise reaching 112 dB. Providing clear sound under these conditions, alongside an initial cabling estimate of approximately 7,000 metres and the constraints of working around production lines, defined the challenge.

Engineering solution

The solution began with site surveys and transducer-placement simulations. Revised cable routes and mounting supports built with the facilities team enabled equipment placement suited to each space. Central processing managed 28 audio zones and 24-zone paging. Dante carried audio between compatible network devices, while Persian panels simplified day-to-day operation.

THE SITE

Height. Noise. Production in motion.

A 22-metre hall and noise measured up to 112 dB at planned transducer locations shaped the design.

Hall height and access constraints
Hall height and access constraints
Stock warehouses and transducer placement
Stock warehouses and transducer placement
Client

Gol Asaye Sarma

Delivery period

Approximately six months

PROJECT AT A GLANCE

Designed for scale

18Functional areas
28Controlled zones
24Paging zones
3Access levels
TECHNOLOGY / SYSTEM

Audio system configuration

Processing and routing: Ecler MIMO 7272 matrix mixer with DN44BOB expansion interfaces

Amplification: eHSA4-500 and eHSA4-250 four-channel amplifiers serving the different areas

DUO-NET PLAYER for scheduled audio playback

PAGENETDN paging station with custom control panels

Coverage adapted to each space: eMSP50Ti Horn-Loaded Transducers for noisy areas, with eCS803 column transducers and IC6 and eLC52 ceiling transducers for offices, corridors and the showroom

Dante audio transport between compatible network devices, with amplifiers and transducers providing final sound distribution

NETWORKED AUDIO EXPERTISE

Dante: networked audio at factory scale

At Depoint Factory, distances between spaces, varied uses and the need for centralised management made audio transport and distribution a key design decision. Dante enabled digital audio transport between compatible devices over the network, connecting different parts of the complex within one integrated architecture.

Delivering such a system goes beyond connecting equipment with network cables. Connection design, audio-channel routing, clock synchronisation and latency settings, network configuration and performance testing require specialist knowledge of both audio and networking. In this project, that expertise worked alongside central Ecler processing and custom Persian panels to make factory-wide audio operation straightforward and unified.

Depoint demonstrates AVASH’s practical experience in designing, configuring and commissioning networked audio systems for large industrial environments.

Audio signal path · conceptual overview
  1. Audio sources & paging

    Music, scheduled content and announcements

  2. Processing & network transport

    Central Ecler processing and Dante links between compatible devices

  3. Amplification & distribution

    Amplifiers and transducer lines

  4. Factory spaces

    Production, storage, offices, showroom and dining

Dante links connect compatible network devices; amplifiers and transducer lines provide final audio distribution.

A closer look at the equipment

Product reference images; photographs and film of the actual installation appear in the project gallery.

Ecler eAMBIT106
Ecler eAMBIT106
Ecler DN44BOB
Ecler DN44BOB
Ecler eCS803
Ecler eCS803
Ecler DUO-NET PLAYER
Ecler DUO-NET PLAYER
Ecler MIMO7272DN
Ecler MIMO7272DN
Ecler eMSP50Ti
Ecler eMSP50Ti
Ecler PAGENETDN
Ecler PAGENETDN
DESIGN DECISIONS

Why these choices mattered

Shorter, lower-risk routes

Cabling alongside active production lines required practical, lower-risk routes. Reviewing routes and selecting suitable shortcuts reduced analogue cabling from an initial estimate of approximately 7,000 metres to 5,800 metres. Network cabling was reduced from an estimated 650 metres to 380 metres.

Transducer selection for noisy areas

After measuring noise levels reaching 112 dB at the transducer positions, a minimum transducer output of 120 dB was set as a selection requirement. This criterion guided equipment selection to overcome ambient noise in the louder areas.

Placement shaped by site conditions

Coverage simulations guided transducer placement. Working with the facilities team, supports reduced mounting height in the main hall from 22 metres to approximately 12 metres. This brought transducers closer to listening areas and supported more suitable coverage.

One operator, role-based access

Persian panels were designed for general users, network users and network administrators. Each role received appropriate controls, enabling an operator to manage the system from network-accessible locations.

ON-SITE ENGINEERING

Precision within a complex structure

Placement simulations, revised cable routes and mounting supports brought design decisions into the working factory.

Industrial Acoustic Network — Horn-Loaded Transducers for High-Noise Environments.

Suspended horn-loaded transducer clusters in Depoint Factory’s production hall
Installation coordinated with ducts and services
Installation coordinated with ducts and services
Supports and transducer placement in the production hall
Supports and transducer placement in the production hall
DAILY OPERATION

Control for day-to-day operation

Ease of operation was central to the design. Custom Persian panels give one operator access to zone control, content playback, volume adjustment and crisis-announcement scenarios. Control is available from network-connected locations, with functions assigned according to each user’s role.

Scheduled audio content tailored to three working shifts
Paging-zone selection, volume adjustment and content management through Persian panels
Dedicated panels for crisis-announcement scenarios
Unified operation by one operator, with functions separated across three access levels
Original PAGENETDN panel with Persian labels and 24 paging-zone buttons
Persian paging and zone-selection panel
Original panel showing individual zone volume controls
Zone volume control

Reliability proven in operation

After approximately six months of continuous work, the factory’s diverse spaces were brought into one integrated audio system. Transducers suited to each area, scheduled playback and Persian control panels support daily music across three shifts while providing the operator with paging and announcement controls.

PROJECT FILM

Inside Depoint Factory

A closer look at the project and audiovisual installation.

Watch the project films

Depoint Factory ←

YOUR SPACE, YOUR REQUIREMENTS

What does your space need?

Tell us about your space and how you plan to use it. Let’s discuss the right audio and video system.
Start a project